PH301 Portable Ultrasonic Flow Meter

Introduction

 

PH301 is a highly accurate and non-invasive portable ultrasonic flow meter for liquid flow measurement. PH301uses the most reliable digital signal processing technology, transmitting flow measurement for a wide range of liquid and pipe size with high accuracy and reliability. It is an ideal tool for testing and validating flow.

 

A pair of transducer are provided for optimal performance with pipes ranging from 1” to 200” in diameter, and it works with most commonly-used and other special pipe materials. Fully equipped carrying case includes a set of complete measurement tools and the charger that can charges for built-in Li-battery, which allow users to measure when and where needed.

 

 

 

Features

 

  Ideal for Monitoring & Measuring Flow

Clamp-on transducers allow for quick installation with no shutdown, no drilling and no pressure drop. Each meter is provided with a built-in SD card making it an ideal solution for monitoring flow over time. Fully equipped carrying case includes a set of complete measurement tools and the rechargeable internal battery makes it the ideal go-anywhere flow meter.

 

  Works with Multi Pipe Materials

It is designed to work with many different pipe materials including PVC, carbon steel, stainless steel, copper, PE, HDPE, ductile iron, aluminum, asbestos and fiber glass-epoxy.

 

  Simple to Set Up and Use

PH301 is easily configured through 4.3 inch TFT colorful screen and 22 touch keys. Enter a few key parameters and the display screen will display the correct transducer spacing distance.

 

  Alphanumeric and Flow Curve Display Completes the Picture

A large, multi-function LCD presents measured data in both alphanumeric and graphic forms. Standard alphanumeric functions include flow velocity, flow, and totalized flow in either English (U.S.) or metric units. In graphic mode, the LCD shows both real time and logged data, which is very useful for reviewing data and observing trends while on the site.

 

 

Product Details

 

Product Details

Easy Measurement Anytime & Anywhere

Fully equipped carrying case includes a set of complete mea.surement tools and the rechargeable internal battery design allows users to take measurement when and where needed.

 

 

 

 

— Real-Time Monitoring of Flow Data

Flow curve display completes the picture and in graphic mode, the colorful screen shows both rea time and logged data, which is very useful for reviewing data and observing trends while on the site.

 

 

 

 

— Data Management on PC

Data in SD card can be transmitted to your PC through a USB cable.

 

 

 

 

 

 

Product Dimension

 

 

 

Technical Data

 

Technical Parameter

 

Velocity Range

0.03~±40ft/s (0.01~±12m/s)

Accuracy

±0.5%

Repeatability

0.15% of measured value

Linerarity

±0.5%

Pipe Size

1" ~ 200" (25mm ~ 5000mm)

Liquid

Water, sea water, diesel oil, alcohol...

Pipe Material

PVC, stainless steel, carbon steel, copper...

Output

Analog output: 4~20mA, max load 750Ω.

Storage

Built-in 2GB SD card, Max: 512 files, Interval: 1~86400s

Power Supply

Rechargeable Li-battery power

Continuous operation of 12 hours

Keypad

22 touch keys

Display

4.3 inch TFT screen, backlight LCD

Temperature

Transmitter: 32℉~140℉ (0℃~60℃)

Transducer: -40℉~248℉ (-40℃~120℃)

Humidity

0 to 99% RH,non-condensing

Transmitter

IP65

Transducer

Encapsulated design, IP68

Standard cable length: 5m

 

Ordering Information

 

PH301

Code

Specification

 

 

 

 

 

 

 

 

 

 

F

Ultrasonic Flow Meter

E

Ultrasonic Energy(BTU) Meter, RTD module  (Need customize)

 

 

 

 

 

 

 

 

Code

Transducer & Guide Rail

CT030

Clamp-on transducer with guide rail

Temperature: -40℉~248℉ (-40℃~120℃) (Standard)

CT031

Clamp-on transducer with magnetic guide rail

Temperature: -40℉~248℉ (-40℃~120℃) (Optional)

 

 

 

 

 

Code

Cable Length

L

Standard cable length: 16ft(5m)

L+

On request other lengths

 

 

Code

Temperature Sensor

PT100

Temperature: 32℉~257℉ (0℃~125℃)

When “Code: E” is chosen, this will be added

 

PH301

F

CT030

L

PT100 Complete ordering information

 

 

 

 

 

Package Content

 

 

 

Installation

 

◆ V Method

The V method is considered as the standard method. It usually gives a more accurate reading and is used on pipe diameters ranging from 25mm to 400mm (1~16”)approximately. Also,it is convenient to use, but still requires proper installation of the transducer, contact on the pipe at the pipe's centerline and equal spacing on either side of the centerline.

 

 

 

◆ Z Method

The V method is considered as the standard method. It usually gives a more accurate reading and is used on pipe diameters ranging from 25mm to 400mm (1~16”)approximately. Also,it is convenient to use, but still requires proper installation of the transducer, contact on the pipe at the pipe's centerline and equal spacing on either side of the centerline.

 

 

◆ N Method

With the N method, the sound waves traverse the fluid twice and bounce three times off the pipe walls. It is suitable for small pipe diameter measurement. The measurement accuracy can be improved by extending the transit distance with the N method (uncommonly used).

 

 

◆ W Method

As with the N method, the measurement accuracy can also be improved by extending the transit distance with the W method. The sound wave traverses the fluid four times and bounces four times off the pipe walls. It is suitable for very small pipe(diameters less than 50mm,2")

 

 

 

 

Application Industry

 

 

Cleaning Industry
  • Measuring Water Usage
  • Monitoring Rinse Water Recovery Systems
  • Quality Control and Compliance

Building Management

  • Central air conditioning
  • Potable water
  • Residential water supply system

HVAC

  • Automated process control
  • Large scale metering projects
  • School, shopping mall, museum, university, office building

Chemical Industry

  • Inbound and outbound raw materials

  • Reaction and separation process control

  • Utility engineering and environmental monitoring

  • Special conditions and media measurement

Water Circulation Industry
  • Water output from water treatment plants

  • Pipeline flow monitoring

  • Energy efficiency monitoring

  • Water resource recycling and utilization

 

 

Velocity Range: 0.03~±40ft/s (0.01~±12m/s)
Accuracy: ±0.5%
Pipe Size: 1'' ~ 200'' (25mm ~ 5000mm)
Liquid: water, sea water, diesel oil, alcohol...
Pipe Material: PVC, stainless steel, carbon steel, copper...
Output: 4-20mA
Power Supply: built-in rechargeable Li-battery