TM601 Compact Ultrasonic Flow Meter
▍Product Information
TM601 is a integrated and compact ultrasonic flow meter, specially designed for meeting the small/middle pipe diameter. It's very easy and simple in setting-up and installation because its small structure.
The product developed by adopting the ultrasonic principle of transit-time difference method sends and receives ultrasonic signals through the sensor. When the ultrasonic signal is transmitted and received through the flowing liquid, there will be a difference between the upstream and downstream transit-time, which can be used to calculating flow and velocity.
◆ Benefits
No Pipe Modification Necessary
|
The difficulties commonly associated with installing a new ultrasonic flow meter are eliminated by simple CLAMP-ON. This design eliminates the need to cut pipe, shut down pipe running, stop production, offer additional costs, and much more. |
No Special Tools Needed
|
All it takes is a single Phillips-head screwdriver to install the TM601 securely to one pipe measured. This ensures that easy and right installation can be achieved by any member of the team without the need for special tools or specialized knowledge. |
Greatly Professional Accuracy
|
Based on the reliable accuracy, TM601 is a allowed to be used for both general sensing applications and situations requiring more precise monitoring, which makes it easier than even before to properly detect flow. The response speed it more up to 0.03m/s. |
▍Product Features
◆ Dimension
Model |
A(mm) |
B(mm) |
C(mm) |
D(mm) Max |
E(mm) |
F(mm) |
G(mm) Max |
Min Pipe |
Max Pipe |
Φ9.53 |
31 |
25 |
7 |
7.5 |
58 |
106 |
70.5 |
Φ9.53 |
Φ12 |
Φ12.7 |
31 |
25 |
7 |
7.5 |
58 |
106 |
70.5 |
Φ12 |
Φ14 |
Φ15 |
31 |
25 |
7 |
7.5 |
58 |
106 |
70.5 |
Φ14 |
Φ16 |
Φ20 |
31 |
25 |
15.8 |
4 |
58 |
106 |
75.8 |
Φ20 |
Φ22 |
Φ25 |
31 |
25 |
14.6 |
4 |
58 |
106 |
74.6 |
Φ25 |
Φ28 |
Φ32 |
31 |
28.5 |
18.5 |
4 |
58 |
106 |
82 |
Φ32 |
Φ35 |
Φ40 |
31 |
29.5 |
23.5 |
7 |
68 |
106 |
91 |
Φ38 |
Φ45 |
Φ50 |
31 |
36 |
27 |
7 |
78 |
106 |
101 |
Φ48 |
Φ54 |
Φ63 |
36 |
41 |
32 |
7 |
91 |
130 |
116 |
Φ58 |
Φ64 |
Φ75 |
36 |
46.5 |
40 |
7 |
105 |
136 |
129.5 |
Φ72 |
Φ78 |
Φ90 |
36 |
53.5 |
47 |
7 |
119 |
150 |
143.5 |
Φ80 |
Φ92 |
◆Available Pipe Size
◆Detectable Liquid
◆Compatible Pipe Material
▍Technical Information
◆ Parameter
Velocity Range |
0.0328~±16ft/s (0.1~±5m/s) |
Accuracy |
±2.0% |
Pipe Size |
DN4 DN8 DN10 DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 |
Liquid |
Regular water, sea water, cooling/hot water, alcohol... |
Pipe Material |
PVC, stainless steel, carbon steel, copper... |
Power Supply |
9 ~ 36V DC, maximum 500mA |
Communication |
Support MODBUS protocol, RS485 |
Analog Output |
4-20mA, Maximum 750Ω |
Alarm Output |
OCT upper and lower limit alarm function (optional) |
Display |
OLED 128*64 dot-matrix display screen |
Key Panel |
Four touch buttons |
Flow Unit |
Support metric unit selection, Cubic Meters(m³), Liters(l), USA Gallons(gal). |
Time Unit |
/hour, /min, The factory default unit is cubic meters per hour. |
Daily, Monthly, and Annual Flow Totalizer |
|
Temperature |
Ambient: 14℉~ +122℉ (-10℃ ~ +50℃) |
Liquid: 14℉~ +122℉ (-10℃ ~ +50℃) |
|
Ambient Humidity |
RH 0~95%, No condensation |
Transmitter |
Die-cast aluminum, IP65, CNC machined |
Housing Material |
Aluminum alloy, CNC machined processing |
Protection Rate |
IP54 |
Cable Length |
6.6ft (2m) standard |
▍Installation
1.Clean the pipe
No dirt and oil contamination outside the pipe.
2.Install the bracket
Align flow meter to the pipe position, install screw on top part of the bracket, and then the bottom part of the bracket will automatically connect with the top part. Fasten the four M4 screws.
3.Install the sensor part
Remove the protection film outside the sensor, put the sensor part into the bracket, and fasten the three M4 screws.
4.Cable Connection
Take out the cable, and fasten it on the socket
5.Operation
Power on and see if the SQ is more than 50 or not. If so, this indicates that the measurement has been stable.
▍Package & Accessory
▍Order Information
TM601 |
Code |
Specification |
||||
|
|
DN |
Inch |
OD |
Pipe Size Range(mm) |
|
A |
DN4 |
1/8’’ |
OD9.53 |
9.5mm~10.5mm |
||
B |
DN8 |
1/4’’ |
OD12.7 |
12.4mm~13.4mm |
||
C |
DN10 |
3/8’’ |
OD15 |
14.5mm~15.4mm |
||
D |
DN15 |
1/2’’ |
OD20 |
16.5mm~23.0mm |
||
E |
DN20 |
3/4’’ |
OD25 |
25.0mm~30.0mm |
||
F |
DN25 |
1’’ |
OD32 |
32.0mm~35.0mm |
||
G |
DN32 |
1-1/4’’ |
OD40 |
38.0mm~45.0mm |
||
H |
DN40 |
1-1/2’’ |
OD50 |
48.0mm~54.0mm |
||
I |
DN50 |
2’’ |
OD63 |
58.0mm~64.0mm |
||
J |
DN65 |
2-1/2’’ |
OD75 |
72.0mm~78.0mm |
||
K |
DN80 |
3’’ |
OD90 |
80.0mm~92.0mm |
||
|
Code |
Output Mode |
||||
1 |
4-20mA+RS485 (If no choice, it will be defaulted) |
|||||
2 |
4-20mA+OCT Pulse |
|||||
|
Code |
Cable Length |
||||
L |
6.6ft(2m) (If no choice, it will be defaulted) |
|||||
L+ |
On request other lengths |
TM601 |
A |
1 |
L |
Complete ordering information |
▍Application Industry
Aquaculture |
|
Swimming Pool System |
|
Irrigation Industry |
|
Cleaning Industry |
|
HVAC |
|
Accuracy: ±2.0%
Pipe Size: DN4 ~ DN80
Liquid: water, sea water, diesel oil, alcohol...
Pipe Material: PVC, stainless steel, carbon steel, copper...
Output: 4-20mA, RS485
Power Supply: 9 ~ 36V DC, maximum 500mA
Liquid: 14℉~ +122℉ (-10℃ ~ +50℃)