TM601 Compact Ultrasonic Flow Meter

Product Information

 

TM601 is a integrated and compact ultrasonic flow meter, specially designed for meeting the small/middle pipe diameter. It's very easy and simple in setting-up and installation because its small structure. 

 

The product developed by adopting the ultrasonic principle of transit-time difference method sends and receives ultrasonic signals through the sensor. When the ultrasonic signal is transmitted and received through the flowing liquid, there will be a difference between the upstream and downstream transit-time, which can be used to calculating flow and velocity.

 

Benefits

 

No Pipe Modification

Necessary

 

The difficulties commonly associated with installing a new ultrasonic flow meter are eliminated by simple CLAMP-ON. This design eliminates the need to cut pipe, shut down pipe running, stop production, offer additional costs, and much more.

No Special Tools

Needed

 

All it takes is a single Phillips-head screwdriver to install the TM601 securely to one pipe measured. This ensures that easy and right installation can be achieved by any member of the team without the need for special tools or specialized knowledge.

Greatly Professional

Accuracy

 

Based on the reliable accuracy, TM601 is a allowed to be used for both general sensing applications and situations requiring more precise monitoring, which makes it easier than even before to properly detect flow. The response speed it more up to 0.03m/s.

 

 

Product Features

 

Dimension

 

 

 

 

Model

A(mm)

B(mm)

C(mm)

D(mm)

Max

E(mm)

F(mm)

G(mm)

Max

Min

Pipe

Max

Pipe

Φ9.53

31

25

7

7.5

58

106

70.5

Φ9.53

Φ12

Φ12.7

31

25

7

7.5

58

106

70.5

Φ12

Φ14

Φ15

31

25

7

7.5

58

106

70.5

Φ14

Φ16

Φ20

31

25

15.8

4

58

106

75.8

Φ20

Φ22

Φ25

31

25

14.6

4

58

106

74.6

Φ25

Φ28

Φ32

31

28.5

18.5

4

58

106

82

Φ32

Φ35

Φ40

31

29.5

23.5

7

68

106

91

Φ38

Φ45

Φ50

31

36

27

7

78

106

101

Φ48

Φ54

Φ63

36

41

32

7

91

130

116

Φ58

Φ64

Φ75

36

46.5

40

7

105

136

129.5

Φ72

Φ78

Φ90

36

53.5

47

7

119

150

143.5

Φ80

Φ92

 

 

 

Available Pipe Size

 

 

 

Detectable Liquid

 

 

 

Compatible Pipe Material

 

 

 

Technical Information

 

Parameter

 

Velocity Range

0.0328~±16ft/s (0.1~±5m/s)

Accuracy

±2.0%

Pipe Size

DN4 DN8 DN10 DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80

Liquid

Regular water, sea water, cooling/hot water, alcohol...

Pipe Material

PVC, stainless steel, carbon steel, copper...

Power Supply

9 ~ 36V DC, maximum 500mA

Communication

Support MODBUS protocol, RS485

Analog Output

4-20mA, Maximum 750Ω

Alarm Output

OCT upper and lower limit alarm function (optional)

Display

OLED 128*64 dot-matrix display screen

Key Panel

Four touch buttons

Flow Unit

Support metric unit selection, Cubic Meters(m³), Liters(l), USA Gallons(gal).

Time Unit

/hour, /min, The factory default unit is cubic meters per hour.

Daily, Monthly, and Annual Flow Totalizer

Temperature

Ambient: 14℉~ +122℉ (-10℃ ~ +50℃)

Liquid: 14℉~ +122℉ (-10℃ ~ +50℃)

Ambient Humidity

RH 0~95%, No condensation

Transmitter

Die-cast aluminum, IP65, CNC machined

Housing Material

Aluminum alloy, CNC machined processing

Protection Rate

IP54

Cable Length

6.6ft (2m) standard

 

 

Installation

 

1.Clean the pipe
No dirt and oil contamination outside the pipe.

 

 

 

2.Install the bracket
Align flow meter to the pipe position, install screw on top part of the bracket, and then the bottom part of the bracket will automatically connect with the top part. Fasten the four M4 screws.

 

 

 

3.Install the sensor part
Remove the protection film outside the sensor, put the sensor part into the bracket, and fasten the three M4 screws.

 

 

 

4.Cable Connection
Take out the cable, and fasten it on the socket

 

 

 

5.Operation
Power on and see if the SQ is more than 50 or not. If so, this indicates that the measurement has been stable.

 

 

 

 

 

Package & Accessory

 

 

 

 

Order Information

 

TM601

Code

Specification

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DN

Inch

OD

Pipe Size Range(mm)

A

DN4

1/8’’

OD9.53

9.5mm~10.5mm

B

DN8

1/4’’

OD12.7

12.4mm~13.4mm

C

DN10

3/8’’

OD15

14.5mm~15.4mm

D

DN15

1/2’’

OD20

16.5mm~23.0mm

E

DN20

3/4’’

OD25

25.0mm~30.0mm

F

DN25

1’’

OD32

32.0mm~35.0mm

G

DN32

1-1/4’’

OD40

38.0mm~45.0mm

H

DN40

1-1/2’’

OD50

48.0mm~54.0mm

I

DN50

2’’

OD63

58.0mm~64.0mm

J

DN65

2-1/2’’

OD75

72.0mm~78.0mm

K

DN80

3’’

OD90

80.0mm~92.0mm

 

 

 

 

 

 

Code

Output Mode

1

4-20mA+RS485 (If no choice, it will be defaulted)

2

4-20mA+OCT Pulse

 

 

 

Code

Cable Length

L

6.6ft(2m) (If no choice, it will be defaulted)

L+

On request other lengths

 

 

TM601

A

1

L

Complete ordering information

 

 

Application Industry

 

 

 

 

 

 

 

 

Aquaculture

  • Recirculating aquaculture system
  • Aquaponics system
  • Indoor farming
Swimming Pool System
  • Private house/villa
  • Indoor pool
  • Large swimming pool

Irrigation Industry

  • Gardening irrigation
  • Irrigation of farmland
  • Drip irrigation
  • sprinkler irrigation

Cleaning Industry

  • Vegetables/fruit
  • Car washing
  • Wafer cleaning

HVAC

  • Automated process control
  • Large scale metering projects
  • School, shopping mall, museum, university, office building

 

Velocity Range: 0.328 ft/s ~ ±16ft/s (0.1m/s ~ ±5m/s)
Accuracy: ±2.0%
Pipe Size: DN4 ~ DN80
Liquid: water, sea water, diesel oil, alcohol...
Pipe Material: PVC, stainless steel, carbon steel, copper...
Output: 4-20mA, RS485
Power Supply: 9 ~ 36V DC, maximum 500mA
Liquid: 14℉~ +122℉ (-10℃ ~ +50℃)