
- HOME
- ABOUT US
- PRODUCTS
- Clamp-on Ultrasonic Meter
- Clamp-on Ultrasonic Flow Meter for Tiny Pipe Size
- Clamp-on Ultrasonic Flow Meter for High Temperature
- Clamp-on Ultrasonic Energy/BTU Meter
- Clamp-on Ultrasonic Meter
- Advanced Clamp-on Ultrasonic Flow Meter
- Ultrasonic Flow Meter With Clamp-on Transducer
TM601
- Clamp-on Ultrasonic Flow Meter for small pipe size
- Colorful Display Screen Clamp-on Ultrasonic Flow Meter
SPLIT/SEPARATE
TM601 Plus
TM601S
TM602
SE603
PORTABLE/HANDHELD
PH301
- Clamp-on Ultrasonic Flow Meter With Guide Rail
- Clamp-on Ultrasonic Flow Meter With Magnetic Guide Rail
FIXED/WALL-MOUNTED
ST501
- Ultrasonic Flow Meter With Clamp-on Transducer
- Ultrasonic Flow Meter With Insertion Transducer
- Clamp-on Ultrasonic Energy/BTU Meter With PT100 Temperature Sensor
ST502
- Ultrasonic Flow Meter With Clamp-on Transducer
- Ultrasonic Flow Meter With Insertion Transducer
- Clamp-on Ultrasonic Energy/BTU Meter With PT100 Temperature Sensor
SE509
- Clamp-on Ultrasonic Energy/BTU Meter With PT1000 Temperature
MU801 Plus
- Two-channels Ultrasonic Flow Meter With Clamp-on Transducer
- Two-channels Ultrasonic Flow Meter With Insertion Transducer
- Four-channels Ultrasonic Flow Meter With Clamp-on Transducer
- Four-channels Ultrasonic Flow Meter With Insertion Transducer
TM605
FL101
- In-Line Ultrasonic Flow Meter
INTEGRATED
TM605P
TM605C
ST505
- INDUSTRIES
- NEWS & EVENTS
- VIDEO
- CONTACT US
ST501 Ultrasonic Flow Meter With Insertion Transducer
▍Product Information
Flo-Instruments ST501 ultrasonic flowmeter offers high-accurate and repeatable flow measurement for liquids at an economical price. It is made of strong metal case. Combined the outstanding performance transducer with high industrial grade material, it's ideal for pipes size from 1''(25mm) up to 48''(1200mm) in diameter. Insertion transducer refers to inserting the transducer into the inside of the pipeline for flow measurement. It can accurately measure the flow rate and flow velocity inside the liquid pipeline. The advantage of the insertion transducer is that it can keep the outer surface of the pipe flat, thereby reducing pressure loss, and has high reliability and measurement accuracy.
◆ Benefits
- Measures the actual flow and total consumption ofvarious liquids
- No loss of process control, optimization of assets and efficiency, no downtime or expense from calibration.
- Adaptive signal processing algorithms optimize performance, ensuring accurate measurements even in challenging flow conditions.
- Clear display interface and LCD display with alarm function, easy to operate and debug
- Utilize transit-time ultrasonic technology so as to realize bi-directional flow measurement by precisely measuring the time it takes for ultrasonic signals to transmit upstream and downstream.
- Leverage the data logging capabilities to analyze historical flow patterns to make system optimization.
- Built-in keypad and simple menu system for fast and easy programming of pipe diameter, pipe material, liquid type, and measurement units.
▍Product Features
◆ Dimension
Transmitter
Transducer
▍Technical Information
◆ Parameter
Performance Specifications | |
Velocity Range |
0.03~±16ft/s (0.01~±5m/s) |
Accuracy |
±1.0% of measured value |
Repeatability |
0.3% of measured value |
Pipe Size |
1" ~ 48" (25mm ~ 1200mm) |
Power Supply |
24V DC |
Keypad |
16 touch keys |
Display | 40 character, 2 line (20×2) lattice alphanumeric, back lit LCD. |
Function Specifications |
|
Output |
Analog output: 4~20mA, max load 750Ω. |
Pulse output: 0~9999Hz, OCT, (min. and max. frequency is adjustable) | |
Relay output: max 1Hz(1A@125V AC or 2A@30V DC) | |
Communication | RS485 |
Liquid |
water, sea water, oil, alcohol... |
Pipe Material | PVC, stainless steel, carbon steel, copper... |
Physical Specifications |
|
Transmitter |
Die-cast aluminum, IP65 |
Transducer |
Encapsulated design, protection grade IP68 |
Double-shielded transducer cable | |
The standard/maximum length of cable: 30ft/1000ft(9m/305m) | |
Temperature |
Transmitter: 32℉~140℉(0℃~60℃) |
Transducer: -40℉~248℉(-40℃~120℃) Standard |
|
Humidity |
Up to 99% RH, non-condensing |
▍Installation & wiring
![]() |
▍Package & Accessory
▍Order Information
ST501 |
Code |
Specification | |||
|
F |
Ultrasonic Flow Meter with Insertion(Standard) | |||
E |
Ultrasonic BTU/Energy Meter with Insertion(Optional) | ||||
|
Code |
Transducer | |||
IT212 | Insertion: Liquid Temp.: -40℉~176℉ (-40℃~80℃) (Standard) |
||||
IT214 | High-temperature Insertion: -40℉~302℉ (-40℃~150℃) (Optional) |
||||
|
Code |
Cable Length |
|||
L |
Standard cable length: 33ft(10m) |
||||
L+ |
On request other lengths |
ST501 |
F |
IT212 |
L |
Complete ordering information |
▍Application Industry
Pharmaceutical
|
|
Building Services |
|
Water and Wastewater |
|
Marine and Shipbuilding |
|
General Industry |
|
Accuracy: ±0.5%
Pipe Size: 1'' ~ 48'' (25mm ~ 1200mm)
Liquid: water, sea water, diesel oil, alcohol...
Pipe Material: PVC, stainless steel, carbon steel, copper...
Output: 4-20mA, RS485, OCT Pulse, Relay...
Transmitter: IP65
Transducer: IP68
-
Office
Floor 15, Building F, Bantian International Center, No.5 Huancheng South Road, Bantian Street, Longgang District, Shenzhen, 518129
Factory
Xinjianxing Science and Technology Park, Fengxin Road, Guangming Street, Guangming New District, Shenzhen, 518107
TEL
+86-0755-28285391
E-mail
flo@flo-instruments.com
Copyright © 2024 All Rights Reserved. Flo-Instruments Co., Ltd.